Specification
N2DG
| Type | N2DG(2 levels above ground)(Lifting Only) | |||
| Power | 3p AC380V 50HZ 3.0KW(N≤6)N=Row | |||
| Motor | Elevation | 2.2KW with brake | ||
| Traversal | ————— | |||
| Front Gate | ————— | |||
| Elevation Speed | 4.0~5.0 m/min | |||
| Traversal Speed | ————— | |||
| Gate Speed | ————— | |||
| Car Limitation | ML-Type(D-Type) | L-Type(T-Type) | ||
| Length MAX. | 5000 | 5300 | ||
| Width MAX. | Body | 1850 | 1900 | |
| Door mirror | 1950 | 2050 | ||
| Between tire | 1800 | 1860 | ||
| Height MAX. | 1550-2050 | 1550-2050 | ||
| Weight MAX. | 2000 | 2350 | ||
| Sound of running | ≤65dB | |||
| Time of exit-entry | 30~60s | |||
| Performance standards | GB17907、JB/T8910 etc. | |||
| Steel-work | □ Structural Steel | |||
| pallet | Splice pallet | |||
| Drive system | Motor with brake | |||
| Control system | PLC | |||
| Elevation | Chain | |||
| Safety Devices | Limit Switch | |||
| Switch for Overrun Prevention | ||||
| Car Detecting Sensor | ||||
| Length Detecting Sensor | ||||
| Positioning Parts | ||||
| Unit-falling Device | ||||
| Emergency Stop Button | ||||
| Alarm Equipment | ||||
| Over current Protection Equipment | ||||
| Detecting Device for Overtime and Short Time | ||||
| Fire-control | Fire hydrant(the responsibility of party-A) | |||
| Drain | Floor drain connecting to the outside(the responsibility of party A) | |||
| Temperature | -5℃~40℃ | |||
SBP2G-P2(+1,-1)
| Type | SBP2G-P2(1 level above ground and 1 level under ground)(Lifting Only) | |||
| Power | 3p AC380V 50HZ 3.0KW(N≤6)N=Row | |||
| Motor | Elevation | 2.2KW with brake | ||
| Traversal | ————— | |||
| Front Gate | ————— | |||
| Elevation Speed | 2.0~3.0 m/min | |||
| Traversal Speed | ————— | |||
| Gate Speed | ————— | |||
| Car Limitation | ML-Type(D-Type) | L-Type(T-Type) | ||
| Length MAX. | 5000 | 5300 | ||
| Width MAX. | Body | 1850 | 1900 | |
| Door mirror | 1950 | 2050 | ||
| Between tire | 1800 | 1860 | ||
| Height MAX. | 1550-2050 | 1550-2050 | ||
| Weight MAX. | 2000 | 2350 | ||
| Sound of running | ≤65dB | |||
| Time of exit-entry | 30~60s | |||
| Performance standards | GB17907、JB/T8910 etc. | |||
| Steel-work | H Structural Steel | |||
| pallet | Splice pallet | |||
| Drive system | Motor with brake | |||
| Control system | PLC | |||
| Elevation | Chain | |||
| Safety Devices | Limit Switch | |||
| Switch for Overrun Prevention | ||||
| Car Detecting Sensor | ||||
| Length Detecting Sensor | ||||
| Positioning Parts | ||||
| Unit-falling Device | ||||
| Emergency Stop Button | ||||
| Alarm Equipment | ||||
| Over current Protection Equipment | ||||
| Detecting Device for Overtime and Short Time | ||||
| Fire-control | Fire hydrant(the responsibility of party-A) | |||
| Drain | Floor drain connecting to the outside(the responsibility of party A) | |||
| Temperature | -5℃~40℃ | |||
SBP2G-P3(+1,-2)
| Type | SBP2G-P3(1 level above ground and 2 levels under ground)(Lifting Only) | |||
| Power | 3p AC380V 50HZ 4.0KW(N≤6)N=Row | |||
| Motor | Elevation | 3.7KW with brake | ||
| Traversal | ————— | |||
| Front Gate | ————— | |||
| Elevation Speed | 2.0~3.0 m/min | |||
| Traversal Speed | ————— | |||
| Gate Speed | ————— | |||
| Car Limitation | ML-Type(D-Type) | L-Type(T-Type) | ||
| Length MAX. | 5000 | 5300 | ||
| Width MAX. | Body | 1850 | 1900 | |
| Door mirror | 1950 | 2050 | ||
| Between tire | 1800 | 1860 | ||
| Height MAX. | 1550-2050 | 1550-2050 | ||
| Weight MAX. | 2000 | 2350 | ||
| Sound of running | ≤65dB | |||
| Time of exit-entry | 30~60s | |||
| Performance standards | GB17907、JB/T8910 etc. | |||
| Steel-work | H Structural Steel | |||
| pallet | Splice pallet | |||
| Drive system | Motor with brake | |||
| Control system | PLC | |||
| Elevation | Chain | |||
| Safety Devices | Limit Switch | |||
| Switch for Overrun Prevention | ||||
| Car Detecting Sensor | ||||
| Length Detecting Sensor | ||||
| Positioning Parts | ||||
| Unit-falling Device | ||||
| Emergency Stop Button | ||||
| Alarm Equipment | ||||
| Over current Protection Equipment | ||||
| Detecting Device for Overtime and Short Time | ||||
| Fire-control | Fire hydrant(the responsibility of party-A) | |||
| Drain | Floor drain connecting to the outside(the responsibility of party A) | |||
| Temperature | -5℃~40℃ | |||
Application
Suit for private club, villas, etc.